簡(jiǎn)介: | Breast Cancer qBiomarker Copy Number PCR Array 乳腺癌qBiomarker拷貝數(shù)PCR芯片 |
提供商: | SABio |
服務(wù)名稱(chēng): | 乳腺癌qBiomarker拷貝數(shù)PCR芯片 |
地區(qū): | 美國(guó) |
“英拜為您實(shí)驗(yàn)加速” 技術(shù)服務(wù)網(wǎng)址:http://hj5388.com/ 服務(wù)熱線:400-696-6643、 18019265738 郵箱:daihp@yingbio.com 、 huizhang1228@foxmail.com Breast Cancer qBiomarker Copy Number PCR Array 乳腺癌qBiomarker拷貝數(shù)PCR芯片
乳腺癌qBiomarker拷貝數(shù)PCR芯片用于研究在人類(lèi)乳腺腫瘤中已報(bào)道發(fā)生頻繁突變的23個(gè)基因的拷貝數(shù)。乳腺癌細(xì)胞的DNA拷貝數(shù)改變預(yù)后的影響,例如,HER2擴(kuò)增或超表達(dá)定義乳腺癌患者HER2 +的子群,是不良結(jié)果的預(yù)后分子標(biāo)記和響應(yīng)anti-HER2靶向療法的預(yù)測(cè)分子標(biāo)記。該芯片上的基因編碼受體,激酶,磷酸酶,和調(diào)節(jié)細(xì)胞周期、生長(zhǎng)因子信號(hào)傳導(dǎo),細(xì)胞粘附等過(guò)程的轉(zhuǎn)錄因子。芯片基于主要文獻(xiàn)和公共數(shù)據(jù)庫(kù),選擇最頻繁擴(kuò)增或缺失且與致癌途徑和乳腺癌生物學(xué)相關(guān)的基因。這個(gè)芯片可能成為幫助乳腺癌樣本進(jìn)行基因型分類(lèi)并驗(yàn)證乳腺癌表型生物標(biāo)記的有效工具。這個(gè)芯片可以使每個(gè)基因在每個(gè)樣本中有四個(gè)重復(fù),同時(shí)包含一個(gè)穩(wěn)定的多拷貝參考實(shí)驗(yàn),通過(guò)適當(dāng)?shù)腄NA插入標(biāo)準(zhǔn)化精確檢測(cè)拷貝數(shù)。簡(jiǎn)單的產(chǎn)品模式和操作程序讓任何一個(gè)具備實(shí)時(shí)定量PCR儀的實(shí)驗(yàn)室都可進(jìn)行常規(guī)可靠的拷貝數(shù)檢測(cè)。 qBiomarker拷貝數(shù)PCR芯片用于分子生物學(xué)應(yīng)用。本產(chǎn)品不用于疾病的診斷、預(yù)防和治療。 ER+/PR+, HER2:CCND1. Gain in ER+ Tumors:AURKA. HER2+:ERBB2. Inflammatory Breast Cancer:ERBB2, MTDH, MYC, PTK2, RB1. Lapatinib Sensitivity:CDKN2A, EGFR, ERBB2. AKT & PI-3-Kinase Signaling:AKT1, PPAPDC1B, PTEN. Apoptosis:BCL2L1, MTDH. Cell Adhesion & Cytoskeleton:CSMD1, PAK1, PTK2. Cell Cycle:AURKA, BCL2L1, CCND1, CDK4, CDKN2A, RB1. DNA Repair:C11orf30 (EMSY), TOP2A. Drug Metabolism:BCHE. NFKB Signaling:MTDH. Receptor Tyrosine Kinases:EGFR, ERBB2, FGFR1, FGFR2. Transcription Factors and Co-Factors:MTDH, MYC, NCOA3, RB1, TFDP1. 工作原理: The Copy Number PCR array is a set of optimized real-time PCR primer assays on 96-well, 100-tube or 384-well plates for measuring changes in copy number. The PCR array performs copy number analysis with real-time PCR sensitivity and the multi-loci profiling capability of a microarray. Simply mix the genomic DNA sample with the appropriate ready-to-use PCR master mix, aliquot equal volumes to each well of the same plate, and then run the real-time PCR cycling program. (Download user manual)
The procedure involves isolating genomic DNA (QIAGEN QIAamp DNA Mini Kit or FFPE Tissue Kit is recommended), qPCR detection on qBiomarker Copy Number PCR Arrays or Assays, and data analysis (using the qBiomarker Copy Number Data Analysis). An optional DNA sample quality control step immediately before the detection array or assay setup allows the user to qualify the DNA samples. Why qBiomarker Copy Number Arrays? Layout and Controls: The PCR Arrays are available in both 96-, 384-well plates and 100-well discs and are used to measure the copy number of 23 or 95 genes related to a disease state or pathway. Each gene/locus-specific assay is repeated in technical quadruplicate as indicated in the figure above. As an example, the first gene in the array is measured in wells A1, C1, E1 and G1. The qBiomarker Multicopy Reference Assay (MRef) is used to normalize the data for differences in the amounts of genomic DNA. The Multicopy Reference Assay is shown in purple in the above figure in wells B12, D12, F12, and H12. You can easily perform a Copy Number PCR Array experiment in your own laboratory, or send your samples to us and take advantage of our PCR Array Services. *: when using qBiomarker SYBR? Green Mastermix. Performance Data: qBiomarker Multicopy Reference Assay
RNaseP gene is not suitable as a normalizer of sample input in cancer cell line DNA samples. The absolute average copy numbers of RNaseP per normal genome copy amount of DNA were determined in two breast cancer cell line (SKBR3 and MCF7) genomic DNAs with the delta delta Ct method, using QIAGEN multi-copy reference assay as the normalization control of DNA input. The absolute copy number of RNaseP per normal genome in the genomic DNA is assumed to be 2. Universal Nature of Multicopy Reference Assay Stable Performance of the Multicopy Reference (MRef) Assay in 129 DNAs from 9 Major Human Populations. The qBiomarker multi-copy reference assay (MRef) and a qBiomarker copy number assay for RB1 were tested against DNAs from 129 healthy individuals from 9 major ethnic populations. Each assay and DNA sample combination was run in quadruple reactions. Delta CT between the average CT of the MRef assay and the RB1 assay was calculated for each individual DNA. The average delta Ct for samples within each ethnic population is plotted. Error bars show the standard deviation of the delta CT within each ethnic population. The RB1 gene is assumed to be present at 2 copies in all healthy individual DNAs. Application Data Aneuploidy StudyqBiomarker Copy Number Assays accurately identify aneuploidy. qBiomarker Copy Number Assays designed to target AR and MECP2 were tested against 4 cell line DNAs containing 1 copy (XY, Coriell NA13619), 2 copies (XX, Coriell NA01921), 3 copies (XXX, Coriell NA03623) and 4 copies (XXXX, Coriell NA11226) of X-chromosome. Chromosomal aberrations had been previously identified by cytogenetic methods. A control assay, targeting a stable, multi-copy region in the human genome, was used to normalize the amount of DNA input. ΔΔCT method was used to calculate the gene copy number, using XX (Coriell NA01921) as a 2-copy reference. Each assay was tested against each sample in quadruple replicate reactions, and a t-test was performed. |